Lokatork.com
Office
София 1404, жк. Гоце Делчев,
бл.258, вх. А
+359 2 9621881
office@lokatork.com
lokatork@outlook.com
Expert Partial Discharge Detector XDP-II™
Expert Partial Discharge Detector XDP-II™
Expert Partial Discharge Detector XDP-II™
Expert Partial Discharge Detector XDP-II™
Expert Partial Discharge Detector XDP-II™
Expert Partial Discharge Detector XDP-II™

Expert Partial Discharge Detector XDP-II™

Art. number:
NDB
Price (BGN):
0.00 лв.
Price (EUR):
€0.00

Description

The XDP-II™ design allows for convenient online measurement and  detection  of  partial  discharge  activity  in  MV  and HV insulating  materials  targeting  applications  such  as  power cable accessories, metal clad switchgear, power transformers, insulators, arresters, cable terminations and switches. When combining with our pico coulombs calibrator and PD coupler, the XDP-II™ now becomes an offline PD test system where pC measurements are made and saved to file.

 Highlights

Online & Offline PD Detection and Analysis Relative dB & pC measurements

Multi-Sensor Capabilities Advanced Noise Rejection

Phase Related Partial Discharge (PRPD) Comprehensible Analysis Software

Minimal Training Requirement NiMH Batteries lasts All Day.

Advanced & Innovative PD Detector

XDP-II™ is perfectly suited f substation environment, fiel and laboratories applications

 20+ years experience in the partial discharge detection and analysis field

Buy   with   confidence.   Training   and   support   is included and provided by ndb Tech’s skilled experts who performed thousands of successful XDP-II™ inspections.

The well-established XDP-II™ is a battery-operated portable device allowing partial discharge detection and analysis. The data is saved in its internal memory for local or further analysis on the PC-based XDP-SOFT™. Paired with the proper accessories, the XDP-II™ becomes a powerful solution for many applications such as Cable Joints and Elbows, Switchgear, Offline, Acoustic, TEV, Rotating machines, Transformer, etc…

  • Easy to use, portable and battery operated
  • pC and dB value display
  • Several display modes for on-site real time analysis and diagnostic
  • Saves the waveform and edge of PD in its memory with the date and time
  • Up to 7.5 hrs autonomy
  • Ultra-versatile instrument
  • Network phase synchronization

Partial Discharge Phenomenon

Partial Discharge (PD) is an electrical discharge that occurs across a localized area of the insulation between two conducting electrodes, without completely bridging the gap. It is mostly found on aging insulation materials of high voltage electrical  apparatus.  This  undesirable  phenomenon  translates  into  raised exploitation costs and questionable reliability, while economic performance and reliability are key criteria in the evaluation of an electricity supplier.

Specifications

© 2026 - Lokatork.com - All rights reserved