| Wind Speed Measurement – Principle |
Ultrasonic |
| Wind Speed Measuring Range |
0–85 m/s |
| Wind Speed Resolution |
0.01 m/s |
| Wind Speed Accuracy |
±0.2 m/s or ±2% of reading, whichever is greater, from 0–65 m/s; ±3% of reading above 65 m/s |
| Wind Direction Measurement – Principle |
Ultrasonic |
| Azimuth Range |
0–360° |
| Elevation Range |
±60° |
| Wind Direction Resolution |
0.1° |
| Wind Direction Accuracy |
±2° RMSE for wind speeds from 2 to 65 m/s; ±3° RMSE above 65 m/s |
| Sonic Temperature – Principle |
Calculated quantity |
| Sonic Temperature Range |
-40 to +60 °C |
| Sonic Temperature Resolution |
0.1 °C |
| Sonic Temperature Accuracy |
±1 °C |
| Barometric Pressure Sensor |
Piezoresistive |
| Barometric Pressure Range |
300–1100 hPa |
| Barometric Pressure Resolution |
0.1 hPa |
| Barometric Pressure Accuracy |
±0.5 hPa from 700–1100 hPa at 20 °C; ±1 hPa from 500–1100 hPa; ±1.5 hPa from 300–500 hPa at T = 0–60 °C |
| Tilt Angle Resolution |
0.05° |
| Tilt Angle Accuracy |
±1° |
| Instrument Supply Voltage |
12–30 V DC; 15–30 V DC for 0–10 V analog output |
| Instrument Power Consumption |
< 8 W |
| Heater Supply Voltage |
24 V DC ±10% |
| Heater Power |
105 W |
| Serial Communication Interfaces |
Galvanically isolated RS232, RS485, RS422, and SDI-12 |
| Communication Protocols |
NMEA, MODBUS-RTU, SDI-12, proprietary ASCII protocol |
| Analog Outputs |
3 galvanically isolated analog outputs for wind speed and direction or U-V-W Cartesian components |
| Analog Output Types |
0/4–20 mA, 0–1 V, 0–5 V, or 0–10 V, depending on model |
| Maximum Load Resistance – Current Output |
500 Ω |
| Minimum Input Resistance – Voltage Output |
10 kΩ |
| Analog Output Update Rate |
4 Hz |
| Measurement Rate |
1–4 measurements/s |
| Wind Speed Averaging Interval |
Configurable from 1 s to 10 min |
| Wind Gust Calculation Interval |
Configurable from 1 s to 10 min |
| Electrical Connection |
19-pole M23 male connector |
| Operating Temperature Range |
-40 to +70 °C |
| Protection Rating |
IP67 according to EN 60529 |
| Corrosion Resistance Test |
MIL-STD-810G Method 509.6 – 48 h exposure + 48 h drying; EN ISO 9227:2017 |
| Anti-Icing / Freezing Rain Test |
MIL-STD-810F Method 521.2 |
| Vibration Resistance Test |
EN 60068-2-6:2008; IEC 60068-2-6:2007 |
| Maximum Wind Speed Without Damage |
100 m/s |
| Weight |
Approx. 2.6 kg |
| Housing Material |
AISI 316 stainless steel |
| Mast Installation |
For mast with Ø40 mm outer diameter and Ø36 mm inner diameter |