| Wind Speed Measurement – Principle |
Ultrasonic |
| Wind Speed Measuring Range – -AL Versions |
0–80 m/s |
| Wind Speed Measuring Range – Versions without T/RH |
0–85 m/s |
| Wind Speed Measuring Range – Versions with T/RH |
0–75 m/s |
| Wind Speed Resolution |
0.01 m/s |
| Wind Speed Accuracy |
±0.2 m/s or ±2% of reading, whichever is greater, from 0–65 m/s; ±3% of reading above 65 m/s |
| Wind Direction Measurement – Principle |
Ultrasonic |
| Wind Direction Range |
0–359.9° |
| Extended Wind Direction Range |
0–539.9°, configurable to prevent analog output oscillation around 0° |
| Wind Direction Resolution |
0.1° |
| Wind Direction Accuracy |
±2° RMSE at wind speeds >2 m/s |
| Barometric Pressure – Option 4 |
Piezoresistive sensor |
| Barometric Pressure Range |
300–1100 hPa |
| Barometric Pressure Resolution |
0.1 hPa |
| Barometric Pressure Accuracy |
±0.5 hPa from 700–1100 hPa at 20 °C; ±1 hPa from 500–1100 hPa; ±1.5 hPa from 300–500 hPa at T = 0–60 °C |
| Compass and Tilt Angles – Option A |
Available |
| Compass / Tilt Resolution |
0.05° |
| Compass / Tilt Accuracy |
±1° |
| Heating – Option R |
Available; standard on -AL models |
| Heater Supply Voltage |
24 V DC ±10% |
| Heater Power Consumption |
20 W; 93 W for -AL versions |
| Temperature – Option 17 |
Pt100 sensor, for technopolymer models only |
| Temperature Range |
-40 to +70 °C |
| Temperature Resolution |
0.1 °C |
| Temperature Accuracy |
±0.15 °C ±0.1% of reading |
| Relative Humidity – Option 17 |
Capacitive sensor, for technopolymer models only |
| Relative Humidity Range |
0–100% RH |
| Relative Humidity Resolution |
0.1% RH |
| RH Accuracy at T = 15–35 °C |
±1.5% RH from 0–90% RH; ±2% RH over the remaining range |
| RH Accuracy at T = -40 to +70 °C |
±(1.5 + 1.5% of reading) % RH |
| Global Solar Radiation – Option P |
Thermopile sensor, for technopolymer models only |
| Solar Radiation Range |
0–2000 W/m² |
| Solar Radiation Resolution |
1 W/m² |
| Solar Radiation Classification |
Spectrally Flat Class C according to ISO 9060:2018 |
| Instrument Supply Voltage, Excluding Heater |
12–30 V DC |
| Supply Voltage for 0–10 V Analog Output |
15–30 V DC |
| Current Consumption, Excluding Heater |
60 mA at 24 V DC |
| Serial Communication Interfaces |
Galvanically isolated RS232, RS485, and RS422 |
| Communication Protocols |
NMEA, MODBUS-RTU, proprietary ASCII protocol |
| Analog Outputs |
2 analog outputs for wind speed and direction or U-V Cartesian velocity components |
| Analog Output Types |
4–20 mA standard; 0–1 V, 0–5 V, or 0–10 V on request |
| Analog Output Update Rate |
4 Hz |
| Analog Output Isolation |
Isolated from the power supply |
| Measurement Interval |
250 ms to 1 s |
| Wind Speed Averaging Interval |
Configurable from 1 s to 10 min |
| Wind Gust Calculation Interval |
Configurable from 1 s to 10 min |
| Electrical Connection |
19-pole M23 male connector |
| Operating Temperature Range |
-40 to +70 °C; -50 to +70 °C for -AL models |
| Protection Rating |
IP66 |
| Corrosion Resistance Test |
MIL-STD-810G Method 509.6 – 48 h exposure + 48 h drying; EN ISO 9227:2017 |
| Anti-Icing / Freezing Rain Test – -AL Models |
MIL-STD-810F Method 521.2 |
| Vibration Resistance Test – -AL Models |
EN 60945:2002 Sect. 8.7; EN 60068-2-6:2008; IEC 60068-2-6:2007 |
| Maximum Wind Speed Without Damage |
90 m/s; 100 m/s for -AL models |
| Weight – Versions without T/RH |
Approx. 640 g |
| Weight – Versions with T/RH |
Approx. 1 kg |
| Weight – -AL Models |
Approx. 1.4 kg |
| Housing – Standard Versions |
ASA with aluminum and AISI 316 metal parts |
| Housing – -AL Models |
Anodized aluminum alloy and AISI 316 |
| Mast Installation |
For mast with Ø40 mm outer diameter and Ø36 mm inner diameter |