| Parameter | Value |
|---|---|
| Anemometric Output Quantities | Wind speed and direction, U-V-W components, speed of sound, sonic temperature |
| Meteorological Output Quantities – HD2003 | Pressure, temperature, relative humidity |
| Heading | Magnetic azimuth via compass |
| Moving Average Periods | 1–60 s / 1–60 min |
| Ultrasonic Measurement Rate | 60 Hz |
| Wind Speed – Units | m/s, cm/s, km/h, knots, mph |
| Wind Speed – Range | 0–70 m/s (252 km/h) |
| Wind Speed – Resolution | 0.01 m/s |
| Wind Speed – Accuracy | ±1% of reading |
| Wind Direction – Azimuth Range | 0–360° |
| Wind Direction – Elevation Range | ±60° |
| Wind Direction – Resolution | 0.1° |
| Wind Direction – Accuracy | ±1° |
| Speed of Sound – Range | 300–380 m/s |
| Speed of Sound – Resolution | 0.01 m/s |
| Speed of Sound – Accuracy | ±1% of reading |
| Sonic Temperature – Range | -40 to +60 °C |
| Sonic Temperature – Resolution | 0.1 °C |
| Sonic Temperature – Accuracy | ±1 °C |
| Compass – Range | 0–360° |
| Compass – Resolution | 0.1° |
| Compass – Accuracy | ±1° |
| Parameter | Value |
|---|---|
| Digitally Transmitted Quantities | Anemometric quantities and compass; for HD2003 also pressure, temperature, and relative humidity |
| Communication Interfaces | RS232, RS422 full-duplex, RS485 MODBUS-RTU, RS485 Multidrop half-duplex |
| Baud Rate | 9600–115200 bit/s |
| Digital Output – Normal Mode (Slow) | 1–3600 s |
| Digital Output – High-Frequency Mode (Fast) | Fixed 50 Hz |
| Standard Analog Outputs – Number | 5, selectable from the available anemometric, compass, and meteorological quantities |
| Standard Analog Output Ranges | 0–20 mA, 4–20 mA, 0–1 V, 0–5 V, 0–10 V, 1–5 V |
| Standard Analog Output Resolution | Up to 14 bits |
| Extended Analog Outputs – Optional | Up to 12 outputs using ICP DAS I-7024® module; must be specified when ordering |
| Extended Analog Output Ranges | 0–20 mA, 4–20 mA, 0–5 V, 0–10 V |
| Extended Analog Output Resolution | 14 bits |
| Extended Analog Outputs – Normal Mode (Slow) | 1–3600 s |
| Extended Analog Outputs – High-Frequency Mode (Fast) | 5–20 Hz depending on baud rate |
| Parameter | Value |
|---|---|
| Supply Voltage | 12–30 V DC |
| Power Consumption | <2 W; typically 110 mA at 15 V DC |
| Power Consumption – Heated Models | <6 W when ambient temperature is not lower than -10 °C |
| Weight – HD2003 | 2.1 kg |
| Weight – HD2003.1 | 1.5 kg |
| Operating Temperature Range | -40 to +60 °C |
| Precipitation Operation | Operation ensured up to 300 mm/h of precipitation |
| Operating Relative Humidity | 0–100% RH |
| Heating Option | Automatic temperature-controlled heating of the ultrasonic transducers to prevent ice and snow formation and ensure correct operation during sleet or snowfall |
| RS422 Option | Integrated 4-wire full-duplex RS422 communication interface; available on request when ordering |