Technical Specifications – Senseca HD29 Series
Measurement Specifications
| Parameter |
Value |
| Air Velocity Sensor |
Thermal |
| Temperature Sensor |
NTC |
| Relative Humidity Sensor |
Capacitive |
Measuring Ranges
| Parameter |
Value |
| Air Velocity – HD29A… / HD29V… – Range 1 |
0.05–1 m/s |
| Air Velocity – Range 2 |
0.1–2 m/s |
| Air Velocity – Range 3 |
0.2–10 m/s |
| Air Velocity – Range 4 |
0.2–20 m/s |
| Air Velocity – HD29S… |
0.05–20 m/s |
| Temperature |
-10 to +60 °C |
| Relative Humidity |
0–100 %RH |
Accuracy
| Parameter |
Value |
| Air Velocity Accuracy Conditions |
At 50 %RH and 1013 hPa |
| HD29A… / HD29V… – Range 1 |
±(0.1 + 3% of measured value) m/s |
| HD29A… / HD29V… – Range 2 |
±(0.15 + 3% of measured value) m/s |
| HD29A… / HD29V… – Range 3 |
±(0.5 + 3% of measured value) m/s |
| HD29A… / HD29V… – Range 4 |
±(0.7 + 3% of measured value) m/s |
| HD29S… at V ≤ 1 m/s |
±(0.1 + 3% of measured value) m/s |
| HD29S… at 1 < V ≤ 2 m/s |
±(0.15 + 3% of measured value) m/s |
| HD29S… at 2 < V ≤ 10 m/s |
±(0.5 + 3% of measured value) m/s |
| HD29S… at 10 < V ≤ 20 m/s |
±(0.7 + 3% of measured value) m/s |
| Temperature Accuracy |
±0.3 °C |
| Relative Humidity Accuracy at T = 15–35 °C |
±1.5 %RH at 10–90 %RH; ±2 %RH over the remaining RH range |
| Relative Humidity Accuracy over the Remaining Temperature Range |
±(1.5 + 1.5% of measured value) %RH |
Resolution – HD29S…
| Parameter |
Value |
| Air Velocity |
0.01 m/s |
| Temperature |
0.1 °C |
| Relative Humidity |
0.1 %RH |
| Air Temperature Compensation for Velocity Measurement |
0 to +80 °C |
Outputs and Power Supply
| Parameter |
Value |
| HD29A… |
Active 4–20 mA analog output |
| HD29V… |
0–10 V DC analog output |
| HD29S… |
RS485, MODBUS-RTU or proprietary ASCII protocol |
| Power Supply – HD29A… / HD29V… |
24 V AC ±10% or 18–40 V DC |
| Power Supply – HD29S… |
18–30 V DC |
| Current Consumption |
<100 mA + output current for HD29A… models |
| Electrical Connection |
Screw terminal block, max. 1.5 mm²; PG9 cable gland |
Operating Conditions and Construction
| Parameter |
Value |
| Operating Temperature – Transmitter Housing |
-10 to +60 °C |
| Operating Temperature – Probe |
-30 to +100 °C |
| Air Velocity Sensor Conditions |
Clean air, RH <80% |
| Storage Temperature |
-10 to +70 °C |
| Housing Material |
ABS |
| Front Labels |
Polycarbonate |
| Probe Stem Material |
Stainless steel |
| Protection Rating |
IP65 |
Ordering Code
| Code / Option |
Description |
| HD29 |
Base series |
| 02 |
2 m cable |
| 05 |
5 m cable |
| 10 |
10 m cable |
| TC1 |
Probe with cable, short stem |
| TC2 |
Probe with cable, medium stem |
| TC3 |
Probe with cable, long stem |
| TO1 |
Horizontal fixed probe, short stem |
| TO2 |
Horizontal fixed probe, medium stem |
| TO3 |
Horizontal fixed probe, long stem |
| 300 |
Air velocity only |
| 370 |
Air velocity and temperature |
| 371 |
Air velocity, temperature and relative humidity |
| A |
Active 4–20 mA analog output |
| V |
0–10 V analog output |
| S |
RS485 digital output |
Probe Stem Lengths
| Model |
TC1 |
TC2 |
TC3 |
TO1 |
TO2 |
TO3 |
| HD29x300 |
145 mm |
245 mm |
345 mm |
150 mm |
250 mm |
350 mm |
| HD29x370 |
175 mm |
275 mm |
375 mm |
180 mm |
280 mm |
380 mm |
| HD29x371 |
215 mm |
415 mm |
565 mm |
215 mm |
415 mm |
565 mm |
Fixing accessories and the PC connection cable must be ordered separately.