The Sonel IRM-1 is a compact instrument for measuring environmental parameters when testing and designing photovoltaic systems. It measures solar irradiance, PV module temperature and ambient temperature, and also records module tilt and orientation. The data can be used to convert measurement results to Standard Test Conditions (STC).
The built-in LoRa interface enables long-range data exchange with the main meter. The reSYNC function automatically synchronises the data when the connection is restored. The built-in logger stores up to 5,000 records and can be used to assess solar irradiance before installing a PV system or to diagnose shading in existing installations.
The IP65-rated enclosure is suitable for outdoor use and demanding conditions.
Housing colour by serial number: Units with serial numbers up to L25272 have a dark housing, except for L24580–L24589, which are white. Units with serial numbers from L25273 have a white housing.
For more information: Sonel IRM-1 official product page
| Parameter | Measuring range | Display range | Resolution | Accuracy |
|---|---|---|---|---|
| Solar irradiance | ||||
| Measurement in W/m² | 100…1400 W/m² | 0…1400 W/m² | 1 W/m² | ±(5% of measured value + 2 digits) |
| Measurement in BTU/ft²·h | 32…444 BTU/ft²·h | 0…444 BTU/ft²·h | 1 BTU/ft²·h | ±(5% of measured value + 2 digits) |
| PV module and ambient temperature | ||||
| Measurement in °C | −20.0…100.0 °C | −20.0…100.0 °C | 0.1 °C | ±(1% of measured value + 5 digits) |
| Measurement in °F | −4.0…212.0 °F | 4.0…212.0 °F | 0.1 °F | ±(1% of measured value + 5 digits) |
| Tilt angle | −90°…+90° | −90°…+90° | 1° | ±2° |
| Direction — compass | 0°…360° | 0°…360° | 1° | ±5° |
Measured value — the value recorded by the instrument.
Note: For temperature measurement in °F, the measuring range starts at −4.0 °F, while the display range starts at 4.0 °F. Values are retained as stated in the supplied specification.