Airly Aura PM & Gas Sensor
Airly Aura
Versatile gas & PM monitoring for targeted environmental insight
Airly Aura offers robust monitoring of PM1, PM2.5, PM10 and selected gas combinations (O2+O3, NO+NO2, or CO+SO2), enabling flexible configuration to match specific local needs. Designed for precision, the device provides real-time data via GSM and is compatible with solar power for off-grid installations. Aura integrates natively with Airly Data Platform, making it easy to analyse, visualise and act on hyperlocal pollution trends.
From tracking roadside NO2 near schools to detecting harmful gases in industrial areas, Aura helps local authorities and businesses identify sources of pollution and implement data-driven interventions while supporting compliance, communication and sustainability efforts.
Airly Aura monitors PM1, PM2.5, PM10 and one of three distinct dual-gas configurations: NO2+O3, NO+NO2, or CO+SO2, alongside temperature, humidity and pressure - delivering real-time, reliable insights tailored to local air quality needs..
Airly Pure measures three key pollutants (PM1, PM2.5, PM10) along with temperature, humidity, and pressure – all in real time, with certified precision.
The full technical specifications and description of the device can be found in the attached product brochure.
Measurements
|
|
Units |
Range |
Resolution |
Typical precision (R2) |
DQO - Typical U(exp) |
Operating life |
|
PM1 |
μg/m³ |
0 - 1,000 μg/m³ |
1 μg/m³ |
> 0.8 |
N/A
|
>3 years |
|
PM2.5 |
μg/m³ |
0 - 1,000 μg/m³ |
1 μg/m³ |
> 0.8 |
< 50% |
>3 years |
|
PM10 |
μg/m³ |
0 - 1,000 μg/m³ |
1 μg/m³ |
> 0.6 |
< 50% |
>3 years |
|
NO2 |
ppb, μg/m³ |
0 - 5000 ppb |
0.1 ppb |
> 0.7 |
< 25% |
2 години |
|
NO |
ppb, μg/m³ |
0 - 5000 ppb |
0.1 ppb |
> 0.7 |
< 25% |
2 години |
|
O3 |
ppb, μg/m³ |
0 - 5000 ppb |
0.1 ppb |
> 0.9 |
< 30% |
2 години |
|
SO2 |
ppb, μg/m³ |
0 - 5000 ppb |
0.1 ppb |
> 0.6* |
< 25% |
2 години |
|
CO |
ppb, μg/m³ |
0 - 5000 ppb |
0.1 ppb |
> 0.9 |
< 25% |
2 години |
|
Temperature |
°C |
-40 - 80 °C |
0.1 °C |
> 0.9 |
N/A |
5 years |
|
Humidity |
%RH |
0-100 %RH |
0.1 %RH |
> 0.9 |
N/A |
5 years |
|
Pressure |
Pa |
300-1100 hPa |
0.1 hPa |
> 0.9 |
N/A |
5 years |
Operating working conditions
|
Operating temperature range |
-40 - 60 °C |
|
Operating RH range |
0 - 99 %RH |
Measurements frequency
|
Sampling interval |
1 - 2 seconds |
|
Averaging interval |
5 - 20 seconds |
|
Sending interval |
15 - 60 minutes |
Enclosure parameters and weight
|
Case material |
Stainless steel |
|
Dimensions |
74 x 112* x 84 mm * without antenna |
|
Dimensions |
490 g |
Power Supply and Energy Consumption
|
Supply Voltage |
5V supplied via the included 110/230V power adapter |
|
Average Power Consumption |
1.2 W |