Мултиметър HT12
DC VOLTAGE
Range Resolution Accuracy Overload protection
0.000 ÷ 340.0mV 0.001mV
±(1.5%rdg+4dgt) 720VDC/AC for 10s
0.000 ÷ 3.400V 0.001V
0.00 ÷ 34.00V 0.01V
0.0 ÷ 340.0V 0.1V
0 ÷ 600V 1V
Impedenza di ingresso: 10MΩ
AC VOLTAGE
Range Resolution Accuracy (50 ÷ 400Hz) Overload protection
0.000 ÷ 3.400V 0.001V
0.00 ±(1.5%rdg+5dgt) 720VDC/AC for 10s ÷ 34.00V 0.01V
0.0 ÷ 340.0V 0.1V
0 ÷ 600V 1V
Input impedance: 10MΩ ; Frequency range: 50Hz ÷400Hz
DC CURRENT (with integrated clamp sensor)
Range Resolution Accuracy Overload protection
0.0 ÷ 60.0A 0.1A ±(2.0%rdg+5dgt) 72A AC/DC for 10s
AC CURRENT (with integrated clamp sensor)
Range Resolution Accuracy Overload protection
0.0 ÷ 60.0A 0.1A ±(2.0%rdg+5dgt) 72A AC/DC for 10s
Frequency range: 50Hz ÷60Hz
RESISTANCE
Range Resolution Accuracy Overload protection
0.0 ÷ 340.0Ω 0.1Ω
±(1.0%rdg+3dgt)
720VDC/AC for 10s
0.000 ÷ 3.400kΩ 0.001kΩ
0.00 ÷ 34.00kΩ 0.01kΩ
0.0 ÷ 340.0kΩ 0.1kΩ
0.000 ÷ 3.400MΩ 0.001MΩ ±(5.0%rdg+5dgt)
0.00 ÷ 34.00MΩ 0.01MΩ ±(15.0%rdg+5dgt)
CONTINUITY TEST
Range Buzzer Measurement range Overload protection
RFREQUECY
Type of measure Range Accuracy Resolution Overload protection
Current 0 ÷ 10kHz
±(0.1%rdg+1dgt) 0.001k÷0.01M
72A AC/DC for 10s
Voltage 0 ÷ 300kHz 720VDC/AC for 10s
| pdf_HT12_EN1-00.pdf | PDF, 115.9 KB | Download |