Reflektometŭr TDR-410
Reflektometŭr TDR-410
The TDR-410 is a reflectometer that detects breaks, shorts, moisture damage, and changes in cable impedance.
The TDR-410 is a reflectometer that detects breaks, shorts, moisture damage and changes in cable impedance.
The backlit display automatically indicates the type of fault and the distance to it. Identifies damage and faults in cables and wires:
» Power cables
» Copper telecommunication cables
» Coaxial cables
» Cable infrastructures
KEY FEATURES:
» Automatic or manual operating mode
» Automatic or manual scan triggering
» Manual triggering of single measurements
» Continuous scanning
» Automatic fault location (AFL)
» Range and sensitivity can be adjusted manually or automatically
» Maximum cable length up to 4000 m / 14000 ft (2.5 miles)
» Dead zone measurement limited to 0.5 m / 1.64 ft
» Adjustable impedance matching
» Distribution factor adjustment from 1% to 99%
» 2.5” LCD display with backlight
» Waterproof, rugged housing IP 54 / NEMA 3
» Small size and weight
» Low power consumption – up to 30 hours of operation with 4 AA batteries
| Parameter | Description |
|---|---|
| measuring ranges | 7 m, 15 m, 30 m, 60 m, 120 m, 250 m, 500 m, 1 km, 2 km, 3 km, 4 km 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000 [ft] |
| accuracy | 1% of selected range |
| resolution | approx. 1% of range |
| minimum cable length | 4 m |
| velocity of propagation | within 1…99% or 1…148 m/μs |
| output impulse | 5 Vp-p for an open circuit |
| output impedance | 25, 50, 75, 100 Ω |
| impulse width | 3 ns…3 μs (depending on the range) |
| scanning type | 2 scans/s or a single scan |
| generated acoustic signal | 810 – 1100 Hz |
| operating time on a full battery | up to 30 hours of continuous scanning |
| power supply | 4 x alkaline batteries 1.5 V AA type |
| auto-off function | 1, 2, 3, 5 minutes or deactivated |
| display | graphical, backlit, 128 x 64 pixels |
| overvoltage protection | 400 V DC / 250 V AC |
| operating temperature | -10...+50°C | 10...122°F |
| storage temperature | -20...+70°C | -4...+158°F |
| electromagnetic compatibility standards (EMC) | EN 61326-1 |
| degree of protection / tightness | IP54 |