The Senseca Aeolus WUS30F is a 3-axis ultrasonic anemometer for wind measurement and monitoring, designed for applications that require reliable data in harsh outdoor conditions with minimal maintenance.

The instrument measures wind speed from 0 to 85 m/s, azimuth from 0 to 360°, and elevation angle of ±60°. In addition to overall wind speed and direction, the anemometer provides U-V-W Cartesian components, Wind Gust values, as well as sonic temperature, barometric pressure, and tilt angles.

The measuring principle uses three pairs of ultrasonic transducers arranged along orthogonal axes, allowing determination of wind intensity and three-dimensional airflow direction without moving mechanical parts. This reduces wear and the need for periodic mechanical maintenance.

For reliable operation at low temperatures, the instrument includes an integrated heating system that helps prevent snow and ice accumulation in the detection area. Heating of the sensor support arms can be enabled or disabled depending on site conditions.

The housing is made of AISI 316 stainless steel and provides IP67 protection, making the anemometer suitable for aggressive atmospheric conditions, including marine environments.

For integration into monitoring and automation systems, the instrument provides galvanically isolated RS232, RS485, RS422, and SDI-12 interfaces, supporting NMEA, Modbus RTU, SDI-12, and proprietary ASCII protocols. It also includes three galvanically isolated analog outputs, which can be assigned to wind speed and direction or to the U-V-W wind components.

The Aeolus WUS30F is suitable for weather stations, wind farms, ports, airports, bridges, buildings, tunnels, and other applications requiring precise 3D airflow measurement.

The anemometer is mounted on a mast with Ø40 mm external diameter and Ø36 mm internal diameter and connects through a 19-pole M23 male connector.

For more information:
https://www.senseca.com/en/product/aeolus-wus30f-ultrasonic-anemometer-for-3-axis-wind-monitoring

Technical Specifications – Senseca Aeolus WUS30F

Measurement Specifications

Parameter Value
Wind Speed Sensor Ultrasonic
Wind Speed Measuring Range 0–85 m/s
Wind Speed Resolution 0.01 m/s
Wind Speed Accuracy ±0.2 m/s or ±2% of measured value, whichever is greater, over 0–65 m/s; ±3% of measured value above 65 m/s
Wind Direction Sensor Ultrasonic
Wind Direction Measuring Range 0–360° azimuth; ±60° elevation
Wind Direction Resolution 0.1°
Wind Direction Accuracy ±2° RMSE for 2 m/s < wind speed <65 m/s; ±3° RMSE for wind speed >65 m/s
Sonic Temperature – Sensor Calculated quantity
Sonic Temperature Range -40 to +60 °C
Sonic Temperature Resolution 0.1 °C
Sonic Temperature Accuracy ±1 °C
Barometric Pressure Sensor Piezoresistive
Barometric Pressure Range 300–1100 hPa
Barometric Pressure Resolution 0.1 hPa
Barometric Pressure Accuracy ±0.5 hPa at 700–1100 hPa and 20 °C; ±1 hPa at 500–1100 hPa and ±1.5 hPa at 300–500 hPa over 0–60 °C
Tilt Angle Resolution 0.05°
Tilt Angle Accuracy ±1°

General Specifications

Parameter Value
Instrument Power Supply 12–30 V DC; 15–30 V DC for 0–10 V output; <8 W
Heating Power Supply 24 V DC ±10%; 105 W
Serial Outputs Galvanically isolated RS232, RS485, RS422, and SDI-12
Communication Protocols NMEA, Modbus RTU, SDI-12, proprietary ASCII
Analog Outputs 3 galvanically isolated analog outputs for wind speed and direction or U-V-W Cartesian components
Analog Output Types 0/4–20 mA; 0–1 V; 0–5 V; 0–10 V, depending on model
Load – Current Output Maximum 500 Ω
Input Resistance – Voltage Output Minimum 10 kΩ
Analog Output Update Rate 4 Hz
Measurement Frequency 1–4 Hz
Wind Speed Averaging Interval Configurable from 1 s to 10 min
Wind Gust Calculation Interval Configurable from 1 s to 10 min
Electrical Connection 19-pole M23 male connector
Operating Temperature -40 to +70 °C
Ingress Protection Rating IP67 according to EN 60529
Corrosion Resistance Test MIL-STD-810G, Method 509.6; 48 h exposure + 48 h drying; EN ISO 9227:2017
Freezing Rain Test MIL-STD-810F, Method 521.2
Vibration Resistance EN 60068-2-6:2008; IEC 60068-2-6:2007
Maximum Wind Speed Without Damage 100 m/s
Weight Approx. 2.6 kg
Housing Material AISI 316
Installation On mast, Ø40 mm external / Ø36 mm internal diameter

Ordering Codes

Code Analog Output
WUS30FA 0/4–20 mA, user-configurable
WUS30FW 0–1 V
WUS30FX 0–5 V
WUS30FY 0–10 V