Home
Products
Environment
Senseca LPS02 Series Spectrally Flat Class B Pyranometer for Global Solar Irradiance Monitoring
Home
Environment
Senseca LPS02 Series Spectrally Flat Class B Pyranometer for Global Solar Irradiance Monitoring
Senseca LPS02 Series Spectrally Flat Class B Pyranometer for Global Solar Irradiance Monitoring
Senseca LPS02
Senseca LPS02 Series Spectrally Flat Class B Pyranometer for Global Solar Irradiance Monitoring
Senseca LPS02
Art. number:
Date published 24.09.2026
Price and Delivery
Fill the request form below to receive a price and delivery offer
Technical Specifications – Senseca LPS02 Series
Technical Specifications According to ISO 9060:2018
| Parameter | Value |
|---|---|
| Classification | Spectrally Flat Class B |
| Response Time (95%) | <10 s |
| Zero Offset – Response to 200 W/m² Thermal Radiation | < |±10| W/m² |
| Zero Offset – Response to a 5 K/h Change in Ambient Temperature | < |±4| W/m² |
| Total Zero Offset, Including Effects a), b), and Other Sources | < |±15| W/m² |
| Long-Term Instability (1 Year) | < |±1| % |
| Non-Linearity | < |±1| % |
| Directional Response | < |±18| W/m² up to 80° with 1000 W/m² beam |
| Spectral Error | < |±0.5| % |
| Temperature Response (-10 to +40 °C) | < |±1.5| % |
| Tilt Response | < |±1| % |
Additional Measurements in Digital Models
| Parameter | Value |
|---|---|
| Internal Temperature – Range | -40 to +80 °C |
| Internal Temperature – Resolution | 0.1 °C |
| Internal Temperature – Accuracy | ±0.5 °C in the 0–60 °C range |
| Internal Relative Humidity – Range | 0–100% RH |
| Internal Relative Humidity – Resolution | 0.1% RH |
| Internal Relative Humidity – Accuracy | ±3% RH at 25 °C and 20–80% RH |
| Internal Pressure – Range | 300–1100 hPa |
| Internal Pressure – Resolution | 0.1 hPa |
| Internal Pressure – Accuracy | ±1 hPa in the 0–60 °C range |
| Tilt Sensor – Range | 0° to ±180° |
| Tilt Sensor – Resolution | 0.1° |
| Tilt Sensor – Accuracy | <0.5° |
General Specifications
| Parameter | Value |
|---|---|
| Sensor | Thermopile |
| Typical Sensitivity | 6–15 µV/(W/m²) |
| Measuring Range | -200 to 4000 W/m² |
| Irradiance Range for Analog Output | 0–2000 W/m² by default; configurable on LPS02Mxx models |
| Resolution | 0.1 W/m² |
| Viewing Angle | 2π sr |
| Spectral Range (50%) | 283–2800 nm |
| Outputs | Depending on model: RS485 Modbus RTU; RS485 Modbus RTU + configurable analog output 4–20 mA, 0–20 mA, 0–1 V, 0–5 V, or 0–10 V; 2-wire 4–20 mA current loop; passive mV output |
| Power Supply – RS485 Output | 7–30 V DC |
| Power Supply – Analog Output | 10–30 V DC |
| Power Supply – 0–10 V Output | 15–30 V DC |
| Consumption – Modbus Output Models | 15 mA at 24 V DC; 21 mA at 12 V DC |
| Consumption – Modbus + Analog Output Models | 37 mA at 24 V DC and Iout = 22 mA; 43 mA at 12 V DC and Iout = 22 mA |
| Connection | 5-pole M12; 8-pole M12 only for LPS02MAx |
| Weight | Approx. 620 g |
| Operating Conditions | -40 to +80 °C; 0–100% RH; maximum altitude 6000 m |
| Bubble Level Accuracy | <0.2° |
| Ingress Protection Rating | IP67 |
| Materials | Housing: anodized aluminium; protection screen: ASA; dome: optical glass |
| MTBF | >10 years |
Ordering Codes
| Code | Description |
|---|---|
| LPS02M00 | Modbus output, without tilt sensor |
| LPS02M0T | Modbus output, with tilt sensor |
| LPS02MA0 | Modbus + configurable analog output, without tilt sensor |
| LPS02MAT | Modbus + configurable analog output, with tilt sensor |
| LPS020C0 | 2-wire 4–20 mA current loop output |
| LPS020P0 | mV output |