Zetron MIC100 Fixed Multi-Gas Detector
Zetron MIC100 Fixed Multi-Gas Detector
MIC100
The Zetron MIC100 is a high-performance fixed multi-gas detector designed for continuous online monitoring of combustible gases, toxic gases, and volatile organic compounds (VOCs) in industrial and potentially explosive environments. The device supports simultaneous detection of up to four gases, providing reliable real-time monitoring, safety alarming, and integration with centralized industrial control, automation, and safety systems.
Depending on the target gases and specific application requirements, the MIC100 can use various detection principles, including catalytic combustion, electrochemical sensing, PID photoionization, thermal conductivity, and infrared NDIR technology. Its modular design with intelligent sensor modules simplifies configuration, routine maintenance, and sensor replacement.
The detector is equipped with an OLED display that provides clear visualization of measured gas concentrations and instrument operating status. Configuration and parameter adjustment can be performed using an infrared remote control without opening the enclosure, improving operational safety in potentially hazardous areas.
To ensure high measurement accuracy and long-term stability, the Zetron MIC100 incorporates multi-point calibration and temperature compensation. The measurement accuracy is ±3% FS, repeatability is ±2%, and the response time for combustible gas configurations is T90 <30 seconds. A one-click factory reset function helps prevent problems caused by accidental or incorrect parameter settings.
The MIC100 supports a standard 4–20 mA analog output and an RS485 digital communication interface. Depending on the selected configuration, the two output types can be used individually or simultaneously. The device also features two passive relay outputs rated at 24 V DC / 2 A for controlling external alarm devices, ventilation systems, shut-off valves, and other safety equipment.
The detector operates from a 24 V DC power supply with a normal operating voltage range of 10–30 V DC. Power consumption is less than 1.5 W for toxic gas configurations and less than 2.5 W for combustible gas configurations.
The enclosure is manufactured from aluminum alloy and features a triple waterproof design with an IP66 ingress protection rating, ensuring reliable operation under demanding industrial conditions. Depending on the target gas configuration, the detector provides Exd IIC T6 Gb explosion-proof certification for combustible gases and Exd ib IIC T6 Gb certification for toxic gases.
The operating temperature range is -20 to +50 °C for toxic gas configurations and -40 to +70 °C for combustible gas configurations. The permissible operating humidity range is 10–95% RH, non-condensing, while the atmospheric pressure range is 86–106 kPa.
The Zetron MIC100 offers flexible installation options, including wall mounting and installation on horizontal or vertical pipes. This allows the detector to be adapted to the structural and operational requirements of different industrial facilities.
The detector is suitable for applications in the oil and gas, chemical, petrochemical, and pharmaceutical industries, gas storage facilities, hazardous material handling and storage areas, laboratories, manufacturing plants, and environmental monitoring systems. Thanks to its capability to simultaneously monitor up to four gases, industrial communication interfaces, and relay outputs, the MIC100 is suitable for integration into comprehensive industrial gas safety and intelligent monitoring systems.
For more information:
https://www.hiyipro.com/sale-13782509-mic100-online-multi-gas-detector-for-combustible-toxic-voc-monitoring-in-industrial-applications.html
| Detection gas | Combustible gas, toxic gas, VOC |
| Detection principle | Catalytic combustion, electrochemical, photoionization, thermal conductivity, infrared NDIR |
| Accuracy | ±3%FS |
| Repeatability | ±2% |
| Response time | T90<30S (combustible gas) |
| Power supply | 24VDC (normal operating voltage range: 10~30VDC) |
| Power consumption |
<1.5W(toxic gas) <2.5W(combustible gas) |
| Output signal |
Three-wire 4~20mA or four-wire RS485 or both output simultaneously Two sets of passive relays (24VDC 2A) |
| Main material | Aluminum Alloy |
| weight | About 2.1kg |
| size | 209*160*86mm (L*W*H) |
| Installation | Wall-mounted, horizontal pipe, vertical pipe |
| Protection level | IP66 |
| Temperature range |
-20℃~50℃(toxic gas) -40℃~70℃(combustible gas) |
| Humidity range | 10~95%RH (no condensation) |
| Pressure Range | 86~106Kpa |
| Explosion-proof certification | Exd IIC T6 Gb (flammable gas), Exd ib IIC T6 Gb (toxic gas) |
| Metrology certification | CPA |
| Implementation Standards |