Senseca AEOLUS-3 3-Axis Ultrasonic Anemometer
Senseca AEOLUS-3
Senseca AEOLUS-3 3-Axis Ultrasonic Anemometer
Senseca AEOLUS-3
Art. number:
Date published 16.09.2026
Price and Delivery
Fill the request form below to receive a price and delivery offer
| Parameter | Value |
|---|---|
| Wind Speed Measurement – Principle | Ultrasonic |
| Wind Speed Measuring Range | 0–85 m/s |
| Wind Speed Resolution | 0.01 m/s |
| Wind Speed Accuracy | ±0.2 m/s or ±2% of reading, whichever is greater, from 0–65 m/s; ±3% of reading above 65 m/s |
| Wind Direction Measurement – Principle | Ultrasonic |
| Azimuth Range | 0–360° |
| Elevation Range | ±60° |
| Wind Direction Resolution | 0.1° |
| Wind Direction Accuracy | ±2° RMSE for wind speeds from 2 to 65 m/s; ±3° RMSE above 65 m/s |
| Sonic Temperature – Principle | Calculated quantity |
| Sonic Temperature Range | -40 to +60 °C |
| Sonic Temperature Resolution | 0.1 °C |
| Sonic Temperature Accuracy | ±1 °C |
| Barometric Pressure Sensor | Piezoresistive |
| Barometric Pressure Range | 300–1100 hPa |
| Barometric Pressure Resolution | 0.1 hPa |
| Barometric Pressure Accuracy | ±0.5 hPa from 700–1100 hPa at 20 °C; ±1 hPa from 500–1100 hPa; ±1.5 hPa from 300–500 hPa at T = 0–60 °C |
| Tilt Angle Resolution | 0.05° |
| Tilt Angle Accuracy | ±1° |
| Instrument Supply Voltage | 12–30 V DC; 15–30 V DC for 0–10 V analog output |
| Instrument Power Consumption | < 8 W |
| Heater Supply Voltage | 24 V DC ±10% |
| Heater Power | 105 W |
| Serial Communication Interfaces | Galvanically isolated RS232, RS485, RS422, and SDI-12 |
| Communication Protocols | NMEA, MODBUS-RTU, SDI-12, proprietary ASCII protocol |
| Analog Outputs | 3 galvanically isolated analog outputs for wind speed and direction or U-V-W Cartesian components |
| Analog Output Types | 0/4–20 mA, 0–1 V, 0–5 V, or 0–10 V, depending on model |
| Maximum Load Resistance – Current Output | 500 Ω |
| Minimum Input Resistance – Voltage Output | 10 kΩ |
| Analog Output Update Rate | 4 Hz |
| Measurement Rate | 1–4 measurements/s |
| Wind Speed Averaging Interval | Configurable from 1 s to 10 min |
| Wind Gust Calculation Interval | Configurable from 1 s to 10 min |
| Electrical Connection | 19-pole M23 male connector |
| Operating Temperature Range | -40 to +70 °C |
| Protection Rating | IP67 according to EN 60529 |
| Corrosion Resistance Test | MIL-STD-810G Method 509.6 – 48 h exposure + 48 h drying; EN ISO 9227:2017 |
| Anti-Icing / Freezing Rain Test | MIL-STD-810F Method 521.2 |
| Vibration Resistance Test | EN 60068-2-6:2008; IEC 60068-2-6:2007 |
| Maximum Wind Speed Without Damage | 100 m/s |
| Weight | Approx. 2.6 kg |
| Housing Material | AISI 316 stainless steel |
| Mast Installation | For mast with Ø40 mm outer diameter and Ø36 mm inner diameter |