Technical Specifications – Senseca HD29 Series
Measurement Specifications
| Parameter | Value |
|---|---|
| Air Velocity Sensor | Thermal |
| Temperature Sensor | NTC |
| Relative Humidity Sensor | Capacitive |
Measuring Ranges
| Parameter | Value |
|---|---|
| Air Velocity – HD29A… / HD29V… – Range 1 | 0.05–1 m/s |
| Air Velocity – Range 2 | 0.1–2 m/s |
| Air Velocity – Range 3 | 0.2–10 m/s |
| Air Velocity – Range 4 | 0.2–20 m/s |
| Air Velocity – HD29S… | 0.05–20 m/s |
| Temperature | -10 to +60 °C |
| Relative Humidity | 0–100 %RH |
Accuracy
| Parameter | Value |
|---|---|
| Air Velocity Accuracy Conditions | At 50 %RH and 1013 hPa |
| HD29A… / HD29V… – Range 1 | ±(0.1 + 3% of measured value) m/s |
| HD29A… / HD29V… – Range 2 | ±(0.15 + 3% of measured value) m/s |
| HD29A… / HD29V… – Range 3 | ±(0.5 + 3% of measured value) m/s |
| HD29A… / HD29V… – Range 4 | ±(0.7 + 3% of measured value) m/s |
| HD29S… at V ≤ 1 m/s | ±(0.1 + 3% of measured value) m/s |
| HD29S… at 1 < V ≤ 2 m/s | ±(0.15 + 3% of measured value) m/s |
| HD29S… at 2 < V ≤ 10 m/s | ±(0.5 + 3% of measured value) m/s |
| HD29S… at 10 < V ≤ 20 m/s | ±(0.7 + 3% of measured value) m/s |
| Temperature Accuracy | ±0.3 °C |
| Relative Humidity Accuracy at T = 15–35 °C | ±1.5 %RH at 10–90 %RH; ±2 %RH over the remaining RH range |
| Relative Humidity Accuracy over the Remaining Temperature Range | ±(1.5 + 1.5% of measured value) %RH |
Resolution – HD29S…
| Parameter | Value |
|---|---|
| Air Velocity | 0.01 m/s |
| Temperature | 0.1 °C |
| Relative Humidity | 0.1 %RH |
| Air Temperature Compensation for Velocity Measurement | 0 to +80 °C |
Outputs and Power Supply
| Parameter | Value |
|---|---|
| HD29A… | Active 4–20 mA analog output |
| HD29V… | 0–10 V DC analog output |
| HD29S… | RS485, MODBUS-RTU or proprietary ASCII protocol |
| Power Supply – HD29A… / HD29V… | 24 V AC ±10% or 18–40 V DC |
| Power Supply – HD29S… | 18–30 V DC |
| Current Consumption | <100 mA + output current for HD29A… models |
| Electrical Connection | Screw terminal block, max. 1.5 mm²; PG9 cable gland |
Operating Conditions and Construction
| Parameter | Value |
|---|---|
| Operating Temperature – Transmitter Housing | -10 to +60 °C |
| Operating Temperature – Probe | -30 to +100 °C |
| Air Velocity Sensor Conditions | Clean air, RH <80% |
| Storage Temperature | -10 to +70 °C |
| Housing Material | ABS |
| Front Labels | Polycarbonate |
| Probe Stem Material | Stainless steel |
| Protection Rating | IP65 |
Ordering Code
| Code / Option | Description |
|---|---|
| HD29 | Base series |
| 02 | 2 m cable |
| 05 | 5 m cable |
| 10 | 10 m cable |
| TC1 | Probe with cable, short stem |
| TC2 | Probe with cable, medium stem |
| TC3 | Probe with cable, long stem |
| TO1 | Horizontal fixed probe, short stem |
| TO2 | Horizontal fixed probe, medium stem |
| TO3 | Horizontal fixed probe, long stem |
| 300 | Air velocity only |
| 370 | Air velocity and temperature |
| 371 | Air velocity, temperature and relative humidity |
| A | Active 4–20 mA analog output |
| V | 0–10 V analog output |
| S | RS485 digital output |
Probe Stem Lengths
| Model | TC1 | TC2 | TC3 | TO1 | TO2 | TO3 |
|---|---|---|---|---|---|---|
| HD29x300 | 145 mm | 245 mm | 345 mm | 150 mm | 250 mm | 350 mm |
| HD29x370 | 175 mm | 275 mm | 375 mm | 180 mm | 280 mm | 380 mm |
| HD29x371 | 215 mm | 415 mm | 565 mm | 215 mm | 415 mm | 565 mm |
Fixing accessories and the PC connection cable must be ordered separately.