Technical Specifications – Senseca PMsense
Particulate Matter (PM)
| Parameter | Value |
|---|---|
| Measuring Principle | Laser scattering |
| Measured Fractions | PM1.0, PM2.5 and PM10 |
| Measuring Range | 0–1000 µg/m³ for each fraction |
| Particle Size Detection Range | Ø 0.3–10 µm |
| Linearity Error | <5% |
| Repeatability | <3% |
| Sensor Warm-Up Time | 15 s |
| Sensor Lifetime – Cyclic Operating Mode | Approx. 5 years with 5-minute cyclic operation (default) |
| Sensor Lifetime – Continuous Operating Mode | >10,000 hours with continuous operation at 1 measurement/s |
| Temperature Drift | <0.01 µg/m³/°C |
CO₂ – PMBsense… Models Only
| Parameter | Value |
|---|---|
| Measuring Principle | Dual-wavelength NDIR |
| Measuring Range | 0–5000 ppm |
| Accuracy | ±(50 ppm + 3% of measured value) at 25 °C and 1013 hPa |
| Response Time | <120 s at an air velocity of 2 m/s |
| Long-Term Stability | 5% of measured value / 5 years |
| Temperature Drift | 1 ppm/°C |
Outputs and Communication
| Parameter | Value |
|---|---|
| Digital Interface | RS485 with MODBUS-RTU or proprietary ASCII protocol |
| PMsense-M / PMBsense-M | RS485 MODBUS-RTU |
| PMsense-A / PMBsense-A | RS485 MODBUS-RTU + 2 analog outputs 4–20 mA |
| PMsense-V / PMBsense-V | RS485 MODBUS-RTU + 2 analog outputs 0–10 V |
| Analog Current Outputs – Version A | 2 × 0/4–20 mA |
| Maximum Load Resistance for Current Output | 500 Ω |
| Analog Voltage Outputs – Version V | 2 × 0–10 V |
| Minimum Input Resistance for Voltage Output | 10 kΩ |
Power Supply and Consumption
| Parameter | Value |
|---|---|
| Power Supply | 7–30 V DC |
| Power Supply for 0–10 V Analog Outputs | 15–30 V DC |
| Current Consumption During Measurement | 25 mA at 24 V DC |
| Current Consumption in Standby Mode | 4 mA, cyclic operating mode only |
| Consumption Note | The specified consumption does not include the current drawn by the analog outputs |
Construction and Operating Conditions
| Parameter | Value |
|---|---|
| Electrical Connection | M12 8-pole circular connector |
| Operating Temperature | -20 to +70 °C |
| Operating Relative Humidity | 0–95 %RH |
| Operating Atmospheric Pressure | 500–1500 hPa |
| Housing Material | Polycarbonate |
| Air Inlet Protection | Rain-proof and UV-resistant inlet air filter |
| Protection Rating | IP53 |
| Weight | 330 g |
Ordering Code
| Code / Option | Description |
|---|---|
| PMsense | Base model for particulate matter measurement |
| Blank | PM measurement only |
| B | PM + CO₂ |
| M | RS485 MODBUS-RTU |
| A | RS485 MODBUS-RTU + 2 analog outputs 4–20 mA |
| V | RS485 MODBUS-RTU + 2 analog outputs 0–10 V |
| /C | With Calibration Report |